[] Planning a Restaurant Bar – How Much Space Do You Need? - ADDMORE

Planning a Restaurant Bar – How Much Space Do You Need?

 In FF&E, CAD SHOP DRAWINGS

When planning a restaurant bar, how large should it be? Discover the secrets of bar planning and how to calculate the area you’ll need.

The following is the interpretation and opinion of Rick Uzubell and covers overlapping requirements of building codes, standards and regulations and is only a general guideline. Consult your local architect for exact information.

When you look at prospective commercial buildings, do they appear abstract? If you’re in the market for a restaurant/bar and don’t know how to select a prospective building to match a given occupancy, you’ve come to the right place! Referring to the sketch at right, let’s again use this 4,700 sq.ft. restaurant/sports bar, which we determined to have an occupancy load of 157, as calculated by the guidelines stipulated in the International Building Code (“IBC”).

BAR DESIGN TIP:

The local fire marshal makes the final determination of stated occupant loads.

Architectural drawing of restaurant / sports bar with an occupancy of 157
ARCHITECTURAL PLAN OF RESTAURANT / SPORTS BAR

PLANNING BUILDINGS FOR PROSPECTIVE RESTAURANT/BARS

When planning new restaurant bars, the facts most hospitality experts agree on are:

  • Back-of-the-house generally accounts for 30 – 40% of the total building area.
  • 60 – 70% of a given building’s space is designated as front-of-the-house, which is the area intended for customers. The 10% variance is normally the result of the complexity of the menu.
  • Sports bars tend to require less kitchen space, whereas fine dining requires more. Also note in this example that the bar and bar dining areas account for nearly 43% of the front-of-the-house area as well as 60% of the total occupant load. Conversely, the non-bar dining accounts for 27% of the front-of-the-house area and 40% of the occupant load. The remaining front-of-the-house space (30%) is dedicated to common areas, as shown in the following tables:
Table 1. Front-Of-The-House Occupancy Analysis
Room Area % of Total
Bar Area
·Bar (seated) 29 18.5
· Bar Dining 65 41.4
Sub-Total 94 59.9
Non-Bar Areas
·Reception 06 3.8
·Dining Room 45 28.7
·VIP Room 12 7.6
Sub-Total 63 40.1
Total 157 100.0
Table 2. Front-Of-The-House Area Analysis
Room Area % of Total
Bar Dining
·Bar (seated) 410 12.7
Bar (tables) 983 30.4
Sub-Total 1,393 43.1
·Non-Bar Dining
·Dining Room 681 21.0
·VIP Room 183 5.7
Sub-Total 864 26.7
Common Areas
·Reception 106 3.3
·Men’s Restroom 140 4.3
·Women’s Restroom 146 4.5
·Hallways 423 13.1
·Vestibule 164 5.0
Sub-Total 979 30.2
Total 3,236 100.0

SAMPLE CALCULATION FOR PLANNING A RESTAURANT BAR

What if you’re planning a restaurant bar with an occupancy load of 100 – how large would your building need to be? The above information will serve as a good template for establishing an approximate building size, but given the variation of kitchen sizes, let’s first focus on how the front-of-the-house space can be predicted. If the above 3,236 sq.ft. front-of-the-house space yields an occupancy of 157, we could predict that an occupancy of 100 would require approximately 2,061 sq.ft. for the front-of-the-house according to the following calculations:

  • 3,236 sq.ft./157 occupants = 20.6 sq.ft./occupant
  • 100 occupants x 20.6 sq.ft./occupant – 2,060 sq.ft.

The overall size of the facility, with 30% of the overall space dedicated to the back-of-the-house can be calculated as follows:

  • 2,060 sq.ft./.7 = 2,944 sq.ft.

The back-of-the-house requirements can be calculated as follows:

  • 2,944 sq.ft. – 2,060 sq.ft. = 884 sq.ft.

So, in round numbers, a 3,000 sq.ft. restaurant/bar would be broken down into 900 sq.ft. for back-of-the-house and 2,100 sq.ft. for front-of-the-house.

DESIGNING TO YOUR CUSTOMERS

The next decision will be the breakdown of the dining seating. In our example, about 1/3 of the overall occupancy is dedicated to dining seating and 2/3 to the bar area. This model is built on the success of the bar and that makes a lot of sense, because the activity of the dining patrons tends to taper-off several hours before closing. Secondly, the dining room is more family-friendly and therefore we want to earmark enough capacity. Planning a restaurant bar with an occupancy of 100 should probably have 40% of its capacity dedicated to dining tables; ten booths would be a solid approach. The remaining 60 patrons could be split between the island bar and adjacent 4-top tables and booths.

WHY PLANNING OPEN SPACE IS SO TRICKY

Planning open space is very deceiving, so a person needs to beware when considering a bar for an open area. Unobstructed sight lines – particularly when accompanied by windows and high ceilings – often lead to misunderstanding the true space. I recall the difficulty a new client was having several years ago when trying to plan an island bar. A new addition was being completed at the time and what initially appeared to be an easy design project ended up being a tight fit! The subject space was 1,000 square feet with roll-up garage doors on three sides, as shown in the plan below.

 

Architectural plan of a large open space for an island bar
A 1,000 SQ.FT. SPACE FOR AN ISLAND BAR

Bars need to be designed from the inside-out. In spite of the large space we had to deal with, it wasn’t obvious to me whether or not an island bar would fit. One of critical design features was to provide a perimeter drink rail with seating. After all, with a river in the backdrop, roll-up doors and perimeter seating was a must. Therefore, I resorted to drawing the bar and seating in section view so I could feel comfortable moving forward with the full design. As shown in the photo below, the section view revealed that we had just enough room to fit the bar!

 

A section view of an island bar depicts how bars are designed from the inside-out
THIS SECTION VIEW DEPICTS WHY BARS NEED TO BE DESIGNED FROM THE INSIDE-OUT

NEW CHANGES TO THE IBC FOR OCCUPANCY A-2

The building code is constantly evolving. According to my good friend, architect Tom Kuhn of CSK Architects:

DESIGN TIP:

As of 2018, IBC now requires businesses in Occupancy A-2 that serve alcohol, any new or existing modified fire area over 1500 sq.ft. are now required to have sprinklers if you wanted to meet current code without implementing work-around design parameters in Chapter 34. Always consult your local architect.

I want to thank our good friends at Bullpen Luxury Sports Bar and Gelsosomo’s Pizza for their courtesy. A great place to hang-out, have pizza and watch the game.

TODAY’S TAKEAWAY:

Restaurants with bars don’t require large waiting areas, as many patrons enjoy waiting at the bar.

 

Recent Posts